Operating Temperature 
Input Voltage Range
Operating Voltage Range
Max Reverse Voltage
Current Consumption
Threshold Current Range
Threshold Position
Maximum Current Range
Maximum Position
Float Position
Modulation Frequency
Output Characteristic
Ramp Time
Fault Detection
Fail-Safe
Environmental Requirements
EMC Requirements
Technology |
-40oC to +85oC
-24V to 130V
9V to 16V @12V, 21V to 32.0V @24V
800V
30mA
Adjustable 0 to 1.5A
Set on Test 0-100% Deflection
Adjustable 0 to 1.5A
Set on Test 0-100% Deflection
Yes
Set on Test 100Hz ±5Hz
Linear
Set on Test 0-2secs
Over Voltage, Overange, Over Current (Short Circuit), Joystick Out of Centre at start, Joystick Dual Decode, Joystick Disconnected, Over-ride
Non Sacraficial
SAE J1455
95/54 EC Emissions and Immunity ISO 10605, Electrostatic Discharge ISO 7637 Transients
Through Hole surface mounts |